Reflections Spas  
 
Swim Spas Hot tubs Best Built Spas Features Dealer Locator About Us Customers Dealers
 

Where Perception Meets Expectation

Reflections Spas
 
 
 

Go Back Using Your Premier or Ultra Spa

A. Displaying Time Or Temperature

Pressing the “PROG” button will switch the display between current time and current water temperature.

B. Water Jet Thereapy

Your spa is equipped with one or two therapy pumps that can be activated as follows.

Jet Button:
SINGLE PUMP SYSTEM
1. Press “JET” to activate the Relaxation Therapy mode.
2. Press “JET” to activate the Power Therapy mode.
3. Press “JET” to turn pump off

DUAL PUMP SYSTEM
1. Press “JET” to activate the Relaxation Therapy mode.
2. Press“JET” to activate pump#1 Power Therapy mode.
3. Press “JET” to activate pump #2 Power Therapy mode.
4. Press “JET” to de-activate pump #1.
5. Press “JET” to de-activate pump #2.

Note that for safety, all jet modes will automatically turn off after 30 minutes. Reactivate any therapy mode as indicated above.

C. Turning On The Light

Your spa is equipped with an underwater light. Press the light button to activate and de-activate the light. If left on, the light will automatically turns itself off after 3 hours.

D. Memory

All settings that are entered into your spa controller will be permanently retained in its solid-state memory. In the event of a power failure, the time will be captured and held until power returns. All settings existing at the time of the power failure will be restored when power returns.

E. System Reset

Anytime there is reason to believe that your spa electronic system is not operating properly, perhaps as a result of lightning or other interference, like your PC at home, your spa system can be simply reset by holding down the “DOWN” arrow button for 5 seconds while in the time display mode. The system will be reset, maintaining all the settings you had in memory.

F. Panel Lock

The spa panel can be locked to keep children or others from using any of the spa functions. To deactivate all buttons, make sure “Time” is displayed. Use “PROG” button to change to “Time” display if needed. Then hold the “UP” arrow button for 5 seconds. Notice the flashing lock icon. The panel is locked. To unlock the panel, hold the “UP” arrow button for 5 seconds again. The flashing lock icon will disappear and all spa functions will be accessible.

G. Freeze Protection

If temperature in the spa plumbing falls below 50 degrees Fahrenheit (10 degrees Celsius) the water pump(s) will turn on soft-mode and run for at least one minute. The display will show “ICE”. After one minute, if the water is still below 50 degrees F (10 degrees Celsius), the heater will turn on and raise the water temperature 10 degrees F.

 

 

 

H. Flow Protection

If the flow of water through the heater is insufficient, the spa controller will automatically turn the heater off to prevent overheating. The display will show “FLO”, indicating a flow restriction caused by a clogged filter, shut gate valves or by a malfunction in the pressure switch. Call for service if you cannot pinpoint the cause.

I. Overheat Protection

If the water temperature inside the spa plumbing reaches 112 F, the display will show “HILI” (High Limit), the heater will be disabled, and the pumps will be turned on low speed. If the water temperature continues to rise and reaches 115 F due to friction in the pumps and plumbing system, the entire system including all pumps will be disabled. In “HILI” condition, DO NOT ENTER THE WATER. Remove the cover and allow the water temperature to cool down to 104 F. Then, reset the system by holding down the “PROG” button for 5 seconds while in time display mode. If the “HILI” message returns, call for service.

J. Add Start Up Chemicals

Carefully follow the directions and add the start-up chemicals recommended to you by your dealer. Contact your dealer to clarify any questions you may have.
Your spa comes ready for the Reflections exclusive “Simple Pure ” natural mineral purification cartridges. Combined with an ozonator, “Simple Pure” will aid in reducing the need for Bromine or other chlorine sanitizers. Simple Pure and ozone will make your spa look cleaner, smell cleaner, feel softer and eliminate skin or eye irritation. Ask your dealer about Reflections Spas' “Simple Pure” sanitizing alternative.

K. Diagnostic

When in temperature set mode ( Heat Icon Flashing), then slowly press the “PROG” button three times. When the screen reads P=2 or P=1 press the “PROG" button once again.

S=3 Indicates that the heater will stay on when the pumps are on at anytime. High or Low speed.

S=2 Indicates that the heater will shut off if either of the large pumps are turned on high speed.

S=1 Indicates that the heater will only run when the primary pump is on low speed. Since the heater is associated with the HEET pump system, the primary pump does not need to be on for the heater to operate. Yet in an effort to control the amperage draw and conserve electricity, the heater will run if the primary pump is turned onto low speed but then shut off while the primary pump goes to high speed or if the secondary pump is turned on high. Once the power level has been set, this does not have to be set each time. It will be entered into the system memory.

Press the “PROG” button once again. The diagnostic test will commence and run for the next three and a half minutes. Anytime during the first minute of testing, you can stop the test by pressing the “PROG” button once.

Upon completion of the test, if everything is operating correctly, the message "GOOD" will be displayed for 30 seconds.


 

 

Find Your Local Dealer Today!
Receive our e-Newsletter

Register to receive exclusive promotion and latest company & industry news.
Reflections Spas Showroom : View Our Portable Hot Tubs

Dealer Locator Exclusive Hot Tub JetsHot tubs Built to Last Reflections Spas CustomersDealer Corner

About Reflections Spas Request a Brochure
Hot tubs Owner's Manuals

© Copyright 2007 Reflections Spas Portable Hot tubs, a Division of DM Industries, Ltd. All Rights Reserved
Reflections Spas is a trademark of DM Industries Ltd. Specifications subject to change without notice.
Web designO