Go Back Premier and Ultra Hot Tubs Operating Instructions

NOTE: For best results, read each step carefully and entirely before proceeding to the next.

Filling Your Spa

Wipe the interior of the spa with a damp, soft cloth to remove any residue that may be on the surface. Fill with a garden hose by inserting the nozzle of the hose in the filter inlet. (After filling is complete, remember to put the filter cartridge in place prior to starting the spa.) As the spa is filling, check in the equipment access area for any leaks. On occasion, it may be necessary to hand tighten a union fitting that may have come loose during transit. Also check that the gate valves are pulled out to the open position and that the hose bib is closed. Continue to fill to the water line.
NOTE: If your water is extremely hard, it is preferable to fill the spa halfway with hard water and the rest with softened water. Never fill the spa entirely with softened water.

Initial Start Up

Your spa has been programmed for your convenience. Once properly connected, the pump and heater will automatically come on, heat the spa to 102 F. Initial temperature, day, and time can be set and changed by following these instructions.

A. Setting Temperature:

1. Press “PROG” to display water temperature.
2. Press “UP” or “DOWN” arrows to choose the desired temperature. Notice the heater icon flashing.
3. Wait 30 seconds or press any function buttons (“Jet” or “Light”) to exit the programming mode.

“F” Fahrenheit Or “C” Celsius Degrees

Your spa has been preset to show the temperature in Fahrenheit “F” degrees. If you desire, you can change to Celsius “C” degrees by entering the temp set routine (Display temperature and then touch the up or down arrow). Then while the numbers are flashing, hold the light button for 10 sec. When the “F” or “C” appears, use the “PROG” button to toggle. To exit this procedure, wait 30 seconds or press any button.

B. Auto Heat And Economy Mode (NOT AVAILABLE ON MODELS WITH OPTIONAL CIRCULATION PUMP)

Spas that do not have the optional circulation pump have been designed to operate in two heater control modes: AUTO HEAT (“AH”) and ECONOMY (“ECO”). In the AUTO HEAT mode, the pump and heater will turn on whenever the water temperature falls 1 degree below the chosen temperature . Your spa has been preset to start upon activation in the AUTO HEAT mode. The spa water will be automatically heated to the temperature you choose or to the preset temperature of 102 F.

In the ECONOMY mode, the pump and heater will only come on during programmed hours. (See “Setting Filtration Hours”). Note that, if at the end of filtration cycle the water is not at the chosen temperature, the pump and heater will not continue to run until that temperature is reached. This mode is used for energy conservation, the same way you would control your heat or air conditioning in your house. The clock icon will be displayed when in ECONOMY mode.

To switch to the ECONOMY mode:

1. Press and hold the “PROG” button for 5 seconds to enter the programming mode. “AH” will flash on the display.
2. Press “UP” or “DOWN” button to change between ECONOMY (ECO) and AUTO HEAT (AH). Observe the clock icon when in ECONOMY mode.
3. Wait 30 seconds or press “Light” button to exit the programming mode.

C. Setting Current Time

1. Press and hold the “PROG” button for 5 seconds to enter the programming mode. “AH” will flash on the display. If you are already in the programming mode, go to step 2 directly.
2. Press “PROG” one more time to show the Hour.Observe the flashing clock icon and PM indicator. No indicator means AM.
3. Press “UP” or “DOWN” to select the current hour.
4. Press “PROG” one more time to show the minutes.
5. Press “UP” or “DOWN” to select the current minute.
6. Wait 30 seconds or press the “LIght” button to exit the programming mode.

D. Setting Filtration Cycles

Filtration cycles have been preset at the factory from 8 AM to 10 AM and from 4PM to 6 PM. They can be changed as follows.

1. Press and hold the “PROG” button for 5 seconds to enter the programming mode. “AH” will flash on the display. If you are already in the programming mode, go directly to step 2.
2. Press “PROG” three times to show the filter cycle schedule. Notice the flashing filter icon.
3. Press “UP” and “DOWN” to change the hour.
4. Press “JET” button to change the filter from “-” (Off) to “F” (ON) or vice versa.
5. Wait 30 seconds or press the “LIGHT” button to exit the programming mode.


 

 

Find Your Local Dealer Today!
Receive our e-Newsletter

Register to receive exclusive promotion and latest company & industry news.
Reflections Spas Showroom : View Our Portable Hot Tubs

Dealer Locator Exclusive Hot Tub JetsHot tubs Built to Last Reflections Spas CustomersDealer Corner

About Reflections Spas Request a Brochure
Hot tubs Owner's Manuals

© Copyright 2007 Reflections Spas Portable Hot tubs, a Division of DM Industries, Ltd. All Rights Reserved
Reflections Spas is a trademark of DM Industries Ltd. Specifications subject to change without notice.
Web designO